Part details:
GE-MK6e IS200TRLYH1D
GE documentation identifies this revision as holding six plug-in magnetic relays configured as Form-C contact outputs, powered and fused to drive external solenoids from a 24 V dc or 125 V dc source. The board provides feedback on each relay circuit, sensed between the NO output terminal and the SOL output terminal, to detect a failed external solenoid. The hardware uses a terminal block accepting up to #12 AWG wire, with connector JA1 used for simplex I/O packs and connectors JR1, JS1, and JT1 used for TMR I/O packs. It should be matched with the compatible PDOA I/O pack where that pairing is used in the site configuration.
This component is typically considered when troubleshooting Mark VIe hardware, replacing a failed module, evaluating repair options, or maintaining spare inventory for turbine control systems. Before installation, verify the catalog number, hardware revision, and associated terminal board or I/O pack configuration against site documentation and OEM requirements. The OEM reference for this listing is GEH-6721 Vol I; GEH-6721 Vol II.
Control system parts are provided by GTC Control Solutions, Inc., a wholly owned subsidiary of B7B. Parts are offered in unused, repaired, or remanufactured condition, subject to availability. Each repaired or remanufactured component undergoes comprehensive functional testing in energized panels to guarantee reliability and performance. We provide detailed test reports and warranties with every repair, giving you confidence in the quality and longevity of your replacement parts.
Specifications
- Part number
- IS200TRLYH1D
- Model
- GE-MK6e
- OEM
- General Electric
- Classification
- Terminal Boards
- Control System / Platform
- GE Mark VIe
- Module Type / Function
- TRLY Relay Output Terminal Board
- I/O Category
- Discrete / Protection I/O
- Channel / Point Count
- 12 relay outputs or 36 mechanical relays / 12 voted outputs depending on revision
- Signal Type / Electrical Interface
- Relay output circuits for 115 Vac and/or 24/48/125 V dc applications as documented
- Power Requirements
- Field supply depends on board revision and relay application
- Primary Connectors / Termination Style
- a terminal block accepting up to #12 AWG wire, with connector JA1 used for simplex I/O packs and connectors JR1, JS1, and JT1 used for TMR I/O packs
- Form Factor / Mounting
- T-type barrier terminal board or safety relay terminal board
- System Architecture / Redundancy Support
- Simplex or TMR depending on revision and I/O pack count
- Associated / Compatible Boards
- PDOA or YDOA I/O pack; WPDF option board where applicable
- OEM Manual Reference
- GEH-6721 Vol I; GEH-6721 Vol II