Part details:
GE-MK6eS IS200TRLYS1B
GE documentation identifies this revision as holding 12 plug-in magnetic relays: the first six relay circuits are jumper-configurable for dry contact, Form-C contact, or solenoid-driving outputs from a 125 V dc, 115/230 V ac, or optional 24 V dc source; the next five relays are unpowered isolated Form-C contacts; the final output is an isolated Form-C contact used for special applications such as ignition transformers. This revision is documented as IEC 61508 safety-certified with the Mark VIeS YDOA I/O pack, across all versions. Connector JA1 is used for simplex applications, with JR1, JS1, and JT1 used for TMR applications.
This component is typically considered when troubleshooting Mark VIeS Safety hardware, replacing a failed module, evaluating repair options, or maintaining spare inventory for turbine control systems. Before installation, verify the catalog number, hardware revision, and associated terminal board or I/O pack configuration against site documentation and OEM requirements. The OEM reference for this listing is GEH-6721 Vol I; GEH-6721 Vol II.
Control system parts are provided by GTC Control Solutions, Inc., a wholly owned subsidiary of B7B. Parts are offered in unused, repaired, or remanufactured condition, subject to availability. Each repaired or remanufactured component undergoes comprehensive functional testing in energized panels to guarantee reliability and performance. We provide detailed test reports and warranties with every repair, giving you confidence in the quality and longevity of your replacement parts.
Specifications
- Part number
- IS200TRLYS1B
- Model
- GE-MK6eS
- OEM
- General Electric
- Classification
- Terminal Boards
- Control System / Platform
- GE Mark VIeS
- Module Type / Function
- TRLY Relay Output Terminal Board
- I/O Category
- Discrete / Protection I/O
- Channel / Point Count
- 12 relay outputs or 36 mechanical relays / 12 voted outputs depending on revision
- Signal Type / Electrical Interface
- Relay output circuits for 115 Vac and/or 24/48/125 V dc applications as documented
- Power Requirements
- Field supply depends on board revision and relay application
- Primary Connectors / Termination Style
- JA1 is used for simplex applications, with JR1, JS1, and JT1
- Form Factor / Mounting
- T-type barrier terminal board or safety relay terminal board
- System Architecture / Redundancy Support
- Simplex or TMR depending on revision and I/O pack count
- Associated / Compatible Boards
- PDOA or YDOA I/O pack; WPDF option board where applicable
- OEM Manual Reference
- GEH-6721 Vol I; GEH-6721 Vol II