Part details:
GE-MK6eS IS200TRPGS1B
GE documentation identifies this revision as providing 3 monitored trip relay outputs when used with the YTURS1A I/O pack. TRPG is documented as working as a board pair with TREG, with power for trip solenoids entering through the TRPG J1 connector. TRPG is also documented as mounting below the PSFD Flame Detector Power Supply, which connects to J3, J4, and J5 on TRPG in a diode-ORed, TMR configuration rated at 335 V dc / 5 mA to power up to eight flame detectors. The hardware uses a box-style terminal block. It should be matched with the compatible TREG terminal board where that pairing is used in the site configuration.
This component is typically considered when troubleshooting Mark VIeS Safety hardware, replacing a failed module, evaluating repair options, or maintaining spare inventory for turbine protection systems. Before installation, verify the catalog number, hardware revision, and associated terminal board or I/O pack configuration against site documentation and OEM requirements. The OEM reference for this listing is GEH-6721 Vol I; GEH-6721 Vol II.
Control system parts are provided by GTC Control Solutions, Inc., a wholly owned subsidiary of B7B. Parts are offered in unused, repaired, or remanufactured condition, subject to availability. Each repaired or remanufactured component undergoes comprehensive functional testing in energized panels to guarantee reliability and performance. We provide detailed test reports and warranties with every repair, giving you confidence in the quality and longevity of your replacement parts.
Specifications
- Part number
- IS200TRPGS1B
- Model
- GE-MK6eS
- OEM
- General Electric
- Classification
- Protection & Safety
- Control System / Platform
- GE Mark VIeS
- Module Type / Function
- TRPG Primary Trip Gas Terminal Board
- I/O Category
- Discrete / Protection I/O
- Channel / Point Count
- 3 monitored trip relay outputs
- Signal Type / Electrical Interface
- Primary gas turbine trip protection signals and flame detector power interface where documented
- Power Requirements
- Trip solenoid power via J1; flame detector power interface where documented
- Primary Connectors / Termination Style
- box-style terminal block
- Form Factor / Mounting
- Safety trip terminal board
- System Architecture / Redundancy Support
- 3-pack primary protection configuration where documented
- Associated / Compatible Boards
- TREG terminal board; YTURS1A I/O pack; PSFD where applicable
- OEM Manual Reference
- GEH-6721 Vol I; GEH-6721 Vol II