Images are representations only. Actual product may vary.
  • GE Turbine Controls
  • GE MK6
  • Protection & Safety

IS215VPROH2B - VPRO Emergency Turbine Protection Board | GE Mark VI | B7B

Add the item to your quote basket and submit the form. We'll check availability and pricing and reply within 1 business day.

Part details:
GE-MK6 IS215VPROH2B

The General Electric IS215VPROH2B (VPRO) is an Emergency Turbine Protection board for GE SPEEDTRONIC™ Mark VI turbine control systems, forming an independent emergency overspeed protection system with associated IS200TPRO and TREG terminal boards. Triple-redundant VPRO boards reside in a protection module separate from the main turbine control, controlling trip solenoids through TREG.

VPRO provides emergency overspeed protection and emergency-stop functions, controlling 12 relays on TREG (nine of which vote in three groups of three to control three trip solenoids). VPROH2B is a lower-power version that omits support for a second TREG board (applications requiring a second TREG on connector J4 must use VPROH1A/H1B instead), and includes an Ethernet connection for IONet communications with the control modules.

For maintenance and procurement teams, IS215VPROH2B should be matched to the existing TPRO/TREG terminal boards per GEH-6421 Volume II before ordering a replacement.

Control system parts are provided by GTC Control Solutions, Inc., a wholly owned subsidiary of B7B. Parts are offered in unused, repaired, or remanufactured condition, subject to availability. Each repaired or remanufactured component undergoes functional testing in energized panels, with test reporting and warranty support provided for repair and lifecycle-extension programs.

Specifications

Part number
IS215VPROH2B
Model
GE-MK6
OEM
General Electric
Classification
Emergency Turbine Protection Board
Manufacturer
General Electric
Control System / Platform
GE Mark VI
Series / Family
GE SPEEDTRONIC™ Mark VI
Module Type / Function
VPRO
I/O Category
Emergency Turbine Protection
Channel / Point Count
Emergency overspeed protection, backup sync check, analog and thermocouple protection inputs
Signal Type / Electrical Interface
Speed pickups, PT voltage, thermocouple, analog, trip interlock, E-stop and trip solenoid control
Network / Communications Interface
IONet status communications; independent protection module interface
Power Requirements
125 V dc input; on-board 5 V dc and 28 V dc supplies
Primary Connectors / Termination Style
J3/J4/J5/J6/J7 front-panel connectors to TPRO/TREG/trip hardware
Form Factor / Mounting
Standalone protection board in turbine protection module
System Architecture / Redundancy Support
Triple redundant independent protection module
Associated / Compatible Boards
TPRO, TREG, TREL, and TRES terminal boards
OEM Manual Reference
GEH-6421K; GEH-6421M
Warranty
Unused:
2 years
Repaired:
2 years
Remanufactured:
3 years

IS215VPROH2B

VPRO Emergency Turbine Protection Board | GE Mark VI | B7B